Customization: | Available |
---|---|
After-sales Service: | on Line Service |
Warranty: | on Line Service |
Still deciding? Get samples of US$ 660/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
pellet stove
Hot Air | Wood Pellet Stove CR-01 | |
|
Nominal output power | 9 KW |
Minimum output power | 3 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 18Kg | |
Pellet hourly consumption (Max) | 1.8Kg/h | |
Pellet hourly consumption(Min) | 0.6Kg/h | |
Automatic Burning Time (Min) | ≈10h | |
Automatic Burning Time(Max) | ≈30h | |
Heat volume | 60-80m2 | |
Efficiency at Max | ≥88% | |
Electronic Consumption | 47-380W | |
Air inlet pipe / smoke outlet pipe | 50/80mm | |
N.W / G.W | 87 / 94.6 Kg | |
Dimension(W*H*D) | 550*950*500mm | |
Package Size(W*H*D) | 600*1090*550mm | |
(By 20'GP /40'HQ container)Loading QTY around72/144PCS |
Hot Air | Hot Selling! Wood Pellets Stove CR-02 Double doors | |
Nominal output power | 9 KW | |
Minimum output power | 3 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 18Kg | |
Pellet hourly consumption (Max) | 1.8Kg/h | |
Pellet hourly consumption (Min) | 0.6Kg/h | |
Automatic Burning Time(Max) | ≈30 h | |
Automatic Burning Time (Min) | ≈10 h | |
Heat volume | 60-80 m2 | |
Efficiency at Max | ≥91% | |
Electronic Consumption | 47-380W | |
Air inlet pipe / smoke outlet pipe | 50/80mm | |
N.W / G.W | 85 / 93 Kg | |
Dimension(W*H*D) | 515*965*490mm | |
Package Size(W*H*D) | 565*1100*550mm | |
(By 20'GP/40'HQ container)Loading QTY around 80//168PCS |
Hot Air | New! Wood Pellets Stove CR-03 | |
Nominal output power | 12 KW | |
Minimum output power | 4 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 18Kg | |
Pellet hourly consumption (Max) | 2.4Kg/h | |
Pellet hourly consumption (Min) | 0.8Kg/h | |
Automatic Burning Time(Max) | ≈22 h | |
Automatic Burning Time (Min) | ≈7 h | |
Heat volume | 80-120 m2 | |
Efficiency at Max | ≥91% | |
Energy efficiency class | A+ | |
Electronic Consumption | 47-380W | |
Air inlet pipe / smoke outlet pipe | 50/80mm | |
N.W / G.W | 99 / 107.6 Kg | |
Dimension(W*H*D) | 505*1035*505mm | |
Package Size(W*H*D) | 550*1165*550mm | |
(By 20'GP/40'HQ container)Loading QTY around 80//168PCS |
Hot Air | New! Wood Pellets Stove CR-04 Double doors | |
Nominal output power | 12 KW | |
Minimum output power | 3 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 17 Kg | |
Pellet hourly consumption (Max) | 2.4 Kg/h | |
Pellet hourly consumption (Min) | 0.6 Kg/h | |
Automatic Burning Time(Max) | ≈28 h | |
Automatic Burning Time (Min) | ≈7 h | |
Heat volume | 80-100 m2 | |
Efficiency at Max | ≥91% | |
Electronic Consumption | 47-380W | |
Air inlet pipe / smoke outlet pipe | 50/80mm | |
N.W / G.W | 101 / 110Kg | |
Dimension(W*H*D) | 610*935*500mm | |
Package Size(W*H*D) | 660*1080*550mm | |
(By 20'GP/40'HQ container)Loading QTY around 72//144PCS |
Hot Air | Hot Selling! Wood Pellet Stove CR-05 | |
|
Nominal output power | 8 KW |
Minimum output power | 3 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 16 Kg | |
Pellet hourly consumption (Max) | 1.6 Kg/h | |
Pellet hourly consumption (Min) | 0.6 Kg/h | |
Automatic Burning Time(Max) | ≈25 h | |
Automatic Burning Time (Min) | ≈10 h | |
Heatable volume | 60-80 m2 | |
Efficiency at Max | ≥90% | |
Electronic Consumption | 40-380W | |
Air inlet pipe / smoke outlet pipe | 50/80mm | |
N.W / G.W | 82.2 / 91.6 Kg | |
Dimension(W*H*D) | 530*923*500mm | |
Package Size(W*H*D) | 590*1070*560mm | |
(By 20'GP/40'HQ container)Loading QTY around 80/168 PCS |
Cautions before Stove Operation
Before stove operation, please make sure all security components have been assembled in accordance with the installation requirement , such as the Flow Control Switch, Safety Valve, and Exhaust Valve etc.
1. The stove must be ground connection. The protection against electric shock relies on the ground connection when basic insulation fails. Please install the appropriate capacity of leakage protector in power supply circuit.
2. The power cord must be replaced by stove manufacturer, local service center or relevant specialist when it is damaged.
3. Do not use stove in the environment which contains explosive of flammable gas, liquid or dust because of the fire.
4. Someone must be on duty during the stove operation.
5. Before stove operation, please make sure that the Water Supply Valve is open and the water tank has been filled with water.
6. Do not place flammable and explosive articles within 0.5 meters of stove and outside smoke vent.
7. Don't place any covering on the stove.
8. Keep elderly and children away from high-temperature parts of stove, such as: Fire Viewing Window Glass, Front Panel, Left & Right Side Panel, Hopper Lid and Exhaust Pipe etc.
9. Please do regular maintenance and cleaning in accordance with maintenance instruction. Before doing maintenance and cleaning, please make sure that stove has been cool down.
10. If a failure occurs, please shut down the power immediately and contact local dealer for a specialist.
Ducted Air | Wood Pellet Stove CR-06P | |
Nominal output power | 9 KW | |
Minimum output power | 3 KW | |
Rating Voltage and Frequency | 220-240V/50Hz 110-120V/60Hz | |
Hopper Capacity | 14Kg | |
Pellet hourly consumption (Max) | 1.8 Kg/h | |
Pellet hourly consumption(Min) | 0.6 Kg/h | |
Automatic Burning Time (Min) | ≈9 h | |
Automatic Burning Time(Max) | ≈23 h | |
Heat volume | 40-80 m2 | |
Efficiency at Max | ≥87% | |
Electronic Consumption | 47-380 w | |
Air inlet pipe / smoke outlet pipe | 50/80 mm | |
N.W / G.W | 83 / 89.6 Kg | |
Dimension(W*H*D) | 797*935*305mm | |
Package Size(W*H*D) | 860*1080*370mm | |
(By 20'GP//40'HQ container)Loading QTY around 72/156PCS |